ü 4 Sets of construction plans ready for Council submission
ü Fully delivered to site within the local Agnes Water area, please enquire if delivery outside of this area
ü Designed for C2 (W63) wind rating for cyclonic areas, please enquire further for other wind zones
ü 1300mm 75 x 75 x 4mm All Gal Steel Stumps for a level site, (600mm out of the ground)
ü Fully engineered LVL H2 treated subfloor to house for termite protection
ü Fully engineered LVL H3 treated subfloor to verandahs for termite and weather protection
ü Wall frames and roof trusses designed and engineered with Pryda Australia Fabrication software with all design and engineering certificates and layouts
ü H2 treated prefabricated 2.4m pine wall frames
ü H2 treated prefabricated pine roof trusses
ü 15mm Ply Flooring through-out and tile underlay to the wet areas
ü Home externally clad with 200mm Smooth Weathertex Cladding
ü Eave Overhangs (size varies each home)- All eave overhangs are fully lined with 4.5 hardiflex eave sheeting
ü Verandah ceilings lined with 4.5 hardiflex sheeting and all joiners and nails to suit (unless otherwise stated)
ü Metal roof battens and treated pine ceiling batten to verandah and soffit areas
ü All nails, bracing ply, cyclone rods, nuts and bolts, washers and straps required for construction
ü 90x19 Yellow Balau hardwood decking and 90x90 Merbau Pencil Round DAR hardwood posts to verandah
ü Fully engineered designed LVL or Hardwood beams to verandahs
ü Zinc corrugated roofing Iron with 125 quad multicote gutters and 180 pre-primed timber fascia
ü Entrance doors, jambs, sills door furniture (satin stainless steel), hinges, screws and door catches
ü Wall and roof sisolation to all roof and wall areas
ü G James aluminium 3mm clear glass sliding windows with flyscreens
ü G James aluminium 3mm clear glass sliding doors with security screens, to suit (sizes vary each house)
LININGS STAGE
ü Metal ceiling batten to internal ceilings
ü 10mm gyprock sheeting for all internals wall and ceilings
ü 6mm villaboard sheeting to wet areas (ie. bathroom, laundry walls)
ü All compounds, adhesives, nails, screws and tape required
ü 90 mm cornice
FIX-OUT STAGE
ü Redicote interior doors, S/S/S door furniture, door catches, hinges and screws to suit
ü FJ pine architraves, skirtings, doors jamb and stop materials
ü MDF shelving to all robes and linen cupboards, with all FJ pine mouldings to suit
ü 16mm Chrome hanging rail to robes, ends and support hangers to suit
ü Door catches and stops
ü All nails, screws, required
ü Internal manhole cover
EXCLUSIONS
-
Electrical
-
Plumbing
-
Kitchen
-
PC Items (bath, shower, vanity, laundry & kitchen sinks etc)
-
Paint
-
Floor Coverings (tile, carpet)
-
Soil Percolation test, slab or pier and subfloor bracing engineering
-
Site Survey; clearing, cutting or disposal of rubbish
-
Labour of Any Kind (advise offered if required)